Fix JOC clipgain, offset_ts, frame status, and renderer state machine

Decode clipgain multiplicatively as 2^(x-4)*(1 + y/32), keep the raw
5-bit offset_ts values and reject frames whose offsets leave 0..23 or are
not strictly increasing, and read the EMDF sample offset as
variable_bits(11). Report parse errors through the frame status: 2
unsupported downmix configuration, 3 object count clamped, 4 parameter
band index, 5 invalid offset_ts, 6 trailing data after byte padding.
Correct the 15/9/5/3 subband-to-parameter-band rows.

Apply the clipgain ramp to the LFE samples before the 1217-sample delay,
stop fading objects in from zero when they have no previous matrix, and
keep disappeared objects published with an all-zero matrix until they
reappear.

Render each frame through the seq state machine: hold the previous
matrices while the decoder is unsynchronized, hard cut on seq 0 or a core
channel count change, and pass the delayed core PCM through when no JOC
metadata is present. Keep the 16-channel output as LFE + 15 objects so
CBA bed channels stay on the fixed-position object path that the ADM,
speaker, and binaural backends already consume.

Update the math notes and README for the multiplicative clipgain, the
no-previous-state interpolation, the LFE gain ramp, and the frame-level
decoding behavior. State that E-AC-3 input without JOC metadata is
outside the supported scope.
This commit is contained in:
TheM14 committed 2026-11-06 11:35:59 +08:00
1 parent 4aef8db36e
commit 0820444f45
8 files changed
+469 -138

No files matched your search

+46 -12
View File
@@ -147,15 +147,17 @@ If the clipgain field consists of integer $x$ and mantissa $y$, then
$$
G_{\mathrm{clip}}=
1+\frac{y}{32}2^{x-4}.
2^{x-4}\left(1+\frac{y}{32}\right).
$$
It is folded into the analysis-side scalar $S=\frac{1}{16}G_{\mathrm{clip}}$, which multiplies
every core-bed sample before the QMF analysis; the $\times16$ after the object inverse QMF cancels the
$1/16$, so the net effect is a multiply by $G_{\mathrm{clip}}$ and the $[-1,1]$ clamp sits **after** the
gain. The scalar keeps two per-frame slots: the first 256 samples of a frame ramp linearly from the
previous frame's value to this frame's value and the rest stays constant, and the first frame after a
reset takes the new value directly. LFE bypasses this scalar.
Its range is $[0.0625,15.75]$; at $x=4$ it reduces to $1+y/32$. It is folded into the analysis-side
scalar $S=\frac{1}{16}G_{\mathrm{clip}}$, which multiplies every core-bed sample before the QMF
analysis; the $\times16$ after the object inverse QMF cancels the $1/16$, so the net effect is a multiply
by $G_{\mathrm{clip}}$ and the $[-1,1]$ clamp sits **after** the gain. The scalar keeps two per-frame
slots: the first 256 samples of a frame ramp linearly from the previous frame's value to this frame's
value and the rest stays constant, and the first frame after a reset takes the new value directly. LFE
uses a separate path but applies the same full $G_{\mathrm{clip}}$ as a sample-wise ramp before its
1217-sample delay; see section 8.
## 3. Parameter-band expansion and time interpolation
@@ -190,7 +192,15 @@ Thus $p(b)=k$ if and only if $b\in\mathcal B_k$. Other parameter-band counts use
### 3.2 One-data-point interpolation
Let $P_{o,c,b}$ be the previous frame-end value and $D_{o,c,p(b)}$ the current target. For slot $t=0\ldots23$:
Let $P_{o,c,b}$ be the previous frame-end value and $D_{o,c,p(b)}$ the current target. When the object
has no previous state yet (the first frame of the stream, or the object's first appearance), all 24 slots
take the current target directly (hard cut, no fade-in from zero):
$$
M_{o,c,b,t}=D_{o,c,p(b)},\qquad t=0\ldots23.
$$
With a previous state, for slot $t=0\ldots23$:
$$
\alpha_t=\frac{t+1}{24},
@@ -208,11 +218,29 @@ $$
M_{o,c,b,23}=D_{o,c,p(b)}.
$$
This value then becomes the previous state for the next frame.
This value then becomes the previous state for the next frame. Once an object's present flag goes from 1
to 0, it keeps being published with an all-zero matrix and its previous state is updated to zero until it
becomes present again.
### 3.3 Multiple data points
When a frame contains two data points, `offset_ts` gives the segment boundary. Each segment uses the same linear relation between the previous and next targets; step mode switches targets at the designated slot.
`offset_ts` gives the first slot at which each data point becomes active, using the raw 5-bit value
(legal range $0\ldots23$); the values of one object must be strictly increasing. In the default mode
(`slope_idx=0`), two data points $D_0$ and $D_1$ interpolate as
$$
M_{o,c,b,t}=
\begin{cases}
(1-\alpha_t)P_{o,c,b}+\alpha_tD_{0}, & t=0\ldots10,\ \alpha_t=\dfrac{t+1}{12},\\[1mm]
D_{0}, & t=11,\\[1mm]
(1-\beta_t)D_{0}+\beta_tD_{1}, & t=12\ldots23,\ \beta_t=\dfrac{t-11}{12}.
\end{cases}
$$
Step mode (`slope_idx=1`) switches targets directly at the designated slots: for $t<o_0$ it keeps the
previous frame-end value $P_{o,c,b}$ (or $D_0$ when no previous state exists), for $o_0\le t<o_1$ it
uses $D_0$, and for $t\ge o_1$ it uses $D_1$; with a single data point it keeps $P$ for $t<o_0$ and uses
$D_0$ from $o_0$ on.
## 4. Analysis QMF for core PCM
@@ -337,15 +365,21 @@ where $r=0\ldots63$. Synthesis state must advance continuously by slot.
## 8. LFE path
LFE bypasses the object matrix and inverse QMF and uses a 1217-sample delay. After the input and output scale factors cancel:
LFE bypasses the object matrix and inverse QMF. The core LFE samples are first multiplied by the
sample-wise gain ramp $G[n]$ (the same full $G_{\mathrm{clip}}$ as section 2.4: for $n<256$,
$G[n]=G_{\mathrm{old}}+n(G_{\mathrm{new}}-G_{\mathrm{old}})/256$; for $n\ge256$, $G[n]=G_{\mathrm{new}}$;
on the first frame or after a reset, $G_{\mathrm{old}}=G_{\mathrm{new}}$). The scaled samples then
enter the 1217-sample delay, and the read-out is only clamped, with no further gain:
$$
y_{\mathrm{LFE}}[n]=
\mathrm{clip}\left(
x_{\mathrm{LFE,core}}[n-1217],-1,1
x_{\mathrm{LFE,core}}[n-1217]\cdot G[n-1217],-1,1
\right).
$$
Here $G[k]$ uses the frame-local position of input sample $k$, i.e. $k\bmod1536$.
## 9. OAMD coordinates